The liquid and lyophilized Cowingene HPV 28 Genotyping Detection Kits use the same 28-type panel, specimen range, 100 Copies/mL limit of detection, and PCR channel requirements. The choice turns on reagent format, storage range, package size, and the way your laboratory receives and holds stock. This comparison links each option to a practical purchasing plan.

HPV Detection Kit Comparison: Liquid or Lyophilized Format?
Illustration for reference; see the product page for actual photos and specifications.
01

Cowingene HPV 28 Genotyping Detection Kit (Liquid)

02

Cowingene HPV 28 Genotyping Detection Kit (Lyophilized)

What stays the same

Both Cowingene HPV 28 Genotyping Detection Kits are in vitro diagnostic tests for qualitative detection of HPV DNA in patient specimens by PCR. Each identifies the same 28 types in eight analyses: HPV 6, 11, 16, 18, 26, 31, 33, 35, 39, 40, 42, 43, 44, 45, 51, 52, 53, 54, 56, 58, 59, 61, 66, 68, 73, 81, 82, and 83.

The analytical scope is therefore the same across the two formats. Both have a limit of detection of 100 Copies/mL. Precision is also aligned: the inter-day, intra-day, inter-batch, and different-operator or site results are all CV ≤5.0% for each HPV type.

Urine, cervical swab, vaginal swab, urethral swab, and residual LBC specimen are validated for both kits. Each is compatible with an open real-time PCR instrument using FAM, VIC/HEX, ROX, and CY5 channels. Examples include ABI 7500, Roche 480, and Bio-Rad CFX96.

Side-by-side specifications

CriterionLiquid kitLyophilized kit
Reagent formatLiquidLyophilized
Reference numbersHP04021V, HP04021YHP04022S, HP04022X
Package sizes20 tests/kit, 50 tests/kit8 tests/kit, 48 tests/kit
Storage condition and period≤−20°C for 18 months2–30°C for 18 months
Detection target28 HPV types in eight analyses28 HPV types in eight analyses
Limit of detection100 Copies/mL100 Copies/mL
Validated specimensUrine, cervical swab, vaginal swab, urethral swab, residual LBC specimenUrine, cervical swab, vaginal swab, urethral swab, residual LBC specimen
Compatible PCR platformOpen real-time PCR instruments with FAM, VIC/HEX, ROX, and CY5 channelsOpen real-time PCR instruments with FAM, VIC/HEX, ROX, and CY5 channels
PrecisionCV ≤5.0% for each HPV type across the stated precision conditionsCV ≤5.0% for each HPV type across the stated precision conditions

Storage is the clearest format difference

The liquid kit is stored at ≤−20°C for 18 months. It suits a laboratory that already allocates frozen storage to PCR reagents and can keep that condition under its receiving and inventory process.

The lyophilized kit is stored at 2–30°C for 18 months. This is a defined temperature range, not a general room-temperature instruction. Your receiving and storage area should remain within 2°C to 30°C for this option.

Picture the first stock handoff. For the liquid kit, prepare the ≤−20°C location before the shipment arrives. For the lyophilized kit, check that the storage area stays within 2°C to 30°C throughout the planned holding period. The preferred format follows the temperature-controlled storage condition your laboratory can maintain consistently.

Package size changes the ordering decision

The liquid kit uses 20-test and 50-test package sizes. Its references are HP04021V for 20 tests/kit and HP04021Y for 50 tests/kit. The lyophilized kit uses 8-test and 48-test packages, with HP04022S for 8 tests/kit and HP04022X for 48 tests/kit.

For a smaller planned order, compare the 20-test liquid reference with the 8-test lyophilized reference. For a larger planned order, compare the 50-test liquid reference with the 48-test lyophilized reference. This keeps the package decision tied to expected specimen volume instead of choosing a format first and adjusting stock later.

A laboratory preparing a first run can map its expected specimens to the smaller package options. A laboratory maintaining a regular testing schedule can compare the two larger package references. Include the requested package size and storage condition in the quotation request so we can match the order to the intended format.

Specimen and instrument fit do not change with format

Both kits cover urine, cervical swab, vaginal swab, urethral swab, and residual LBC specimen. A laboratory handling more than one of these specimen categories can keep the same specimen plan while comparing liquid and lyophilized reagents.

The PCR requirement is also shared. Your instrument should be an open real-time PCR machine with FAM, VIC/HEX, ROX, and CY5 channels. ABI 7500, Roche 480, and Bio-Rad CFX96 are examples named for the kits. Match the instrument model and channel configuration to the planned HPV workflow before placing the order.

We also supply supporting collection products for cervical, urethral, and vaginal swabs or urine, together with DNA/RNA extraction products for column-spin, manual, single-test automatic, and multi-test automatic workflows. Those options can be considered alongside either kit format when you are assembling the specimen-to-result workflow.

Which option fits the purchasing plan?

Choose the liquid HPV detection kit when ≤−20°C storage is already part of your laboratory setup and 20- or 50-test packages match your order volume. Choose the lyophilized kit when your facility can hold the product within 2°C to 30°C and the 8- or 48-test packages fit the planned quantity.

Neither format changes the 28-type detection panel, 100 Copies/mL limit of detection, validated specimen categories, PCR channel requirements, or precision value. The decision rests on reagent form, temperature range, and package size. Use the HPV 28 Genotyping Detection Kit product page to identify the product line, then send us the preferred format, reference number, quantity, storage condition, specimen types, and instrument model for a quotation.

Questions about the purchase details

Do both formats carry the same certification?

Yes. Both the liquid and lyophilized kits are identified as CE-IVD. The certification entry is shared across the two product formats, while the reference numbers and package sizes differ. Include the intended format, package quantity, and destination market in your purchasing file so the selected reference is clear during quotation and internal review.

Which substances are listed as not affecting the test results?

The same interference list applies to both formats: hemoglobin at 200 mg/L, white blood cells at 10^9, metronidazole at 2 mg/mL, cervical mucus, Jieeryin lotion, Fuyanjie lotion, and human lubricant. This information is useful when your specimen workflow may contain these substances. Keep the list with the product review for both format options.

Can HPV types in the same HPV mix affect one another?

No. The competitive-interference result for both formats states that the HPV types tested in the same HPV mix do not affect the test results of others. This applies to the shared 28-type detection scope. It gives your technical review a format-specific point to record separately from storage, package size, and instrument selection.

Send the format details with the quote request

The liquid option fits frozen storage at ≤−20°C with 20- or 50-test packages. The lyophilized option fits storage at 2–30°C with 8- or 48-test packages. Both use the same panel and PCR channel configuration. Send us your preferred reference, quantity, specimen categories, instrument model, channel configuration, and storage condition with the quotation request.

The company

Taizhou Cowingene Biotech Co.,Ltd.

As a young and dynamic company, we specialize in developing and manufacturing molecular POCT in vitro diagnostic reagents. With a professional team and a spirit of innovation, we are committed to advancing health management to be more efficient, accessible, and intelligent—becoming a trusted partner in the field of molecular diagnostics..…