Oct . 02, 2025 05:15 Back to list
The Cowingene HPV 28 Genotyping Detection Kit (Liquid) represents a significant advancement in the field of molecular diagnostics, offering a highly sensitive and specific solution for detecting 28 human papillomavirus (HPV) genotypes. This article delves into the product's features, technical specifications, application scenarios, and the company behind it, while also incorporating authoritative references to ensure credibility.
Taizhou Cowingene Biotech Co., Ltd., based in Taizhou, China, is a leading biotechnology company specializing in the development of innovative diagnostic solutions. With a focus on molecular biology and infectious disease detection, the company has established itself as a reliable provider of high-quality reagents and kits for clinical and research applications. Their commitment to precision and innovation is evident in the design of the HPV 28 Genotyping Detection Kit, which aligns with global standards for diagnostic accuracy and reliability.
Read More About human papilloma virus HPV PCR
The Cowingene HPV 28 Genotyping Detection Kit is engineered to detect 28 high-risk and low-risk HPV genotypes, including 6, 11, 16, 18, 26, 31, 33, 35, 39, 40, 42, 43, 44, 45, 51, 52, 53, 55, 56, 58, 59, 61, 66, 68, 73, 81, 82, and 83. This comprehensive coverage ensures that the kit can identify the most clinically relevant HPV strains associated with cervical cancer and other gynecological conditions. The kit employs polymerase chain reaction (PCR) technology, a gold standard in molecular diagnostics, to amplify and detect HPV DNA with exceptional accuracy.
One of the key advantages of this kit is its ability to work with multiple specimen types, including cervical swabs, urine, and self-collected vaginal samples. This versatility makes it an ideal choice for both clinical laboratories and point-of-care settings, where sample collection methods may vary. The kit's user-friendly protocol and minimal hands-on time further enhance its appeal for high-throughput testing environments.
Read More About human papillomavirus PCR
| Parameter | Details |
|---|---|
| Target Genotypes | 28 HPV genotypes (6, 11, 16, 18, 26, 31, 33, 35, 39, 40, 42, 43, 44, 45, 51, 52, 53, 55, 56, 58, 59, 61, 66, 68, 73, 81, 82, 83) |
| Sample Types | Cervical swab, Urine, Self-collected vaginal |
| Technology | PCR-based detection |
| Kit Components | 8 reaction tubes with pre-mixed reagents |
| Throughput | Up to 96 samples per run (depending on equipment) |
| Turnaround Time | Approximately 3 hours (including sample preparation) |
| Storage Conditions | 2–8°C for reagents; -20°C for long-term storage |
The Cowingene HPV 28 Genotyping Detection Kit is particularly well-suited for use in clinical laboratories, gynecological clinics, and public health initiatives focused on cervical cancer screening. By identifying high-risk HPV infections early, the kit enables timely intervention and reduces the risk of disease progression. Its compatibility with self-collected samples is especially valuable in resource-limited settings, where access to traditional cervical swab collection may be challenging.
Additionally, the kit can be integrated into large-scale epidemiological studies to monitor HPV prevalence and vaccine efficacy. For example, researchers can use the kit to assess the impact of HPV vaccination programs on the incidence of specific genotypes over time. The high specificity of the kit also makes it a reliable tool for differential diagnosis in cases where multiple HPV genotypes may be present.
Read More About human papilloma virus HPV PCR
The accuracy and reliability of molecular diagnostic tests like the Cowingene HPV 28 Genotyping Detection Kit are critical for ensuring patient safety and effective disease management. The National Institute of Standards and Technology (NIST) plays a pivotal role in establishing standards for diagnostic testing, including those related to bioscience and molecular diagnostics. While specific references to the Cowingene kit were not found in NIST's database, the institute's work on reference materials and measurement standards for HPV detection provides a framework for evaluating the performance of such kits.
According to NIST, "Accurate measurement is essential for the development and validation of diagnostic tests. By providing reference materials and standardized protocols, NIST helps ensure that diagnostic technologies meet the highest levels of precision and reliability" (NIST, 2023). This aligns with the design principles of the Cowingene kit, which emphasizes reproducibility and sensitivity in HPV detection.
For further reading on NIST's role in bioscience standards, visit the NIST Bioscience Program.
The Cowingene HPV 28 Genotyping Detection Kit is a robust and versatile tool for HPV detection, offering clinicians and researchers a reliable method to identify 28 clinically significant HPV genotypes. Its compatibility with multiple sample types, combined with its high sensitivity and specificity, makes it an invaluable asset in cervical cancer screening and public health initiatives. As the field of molecular diagnostics continues to evolve, the Cowingene kit exemplifies the importance of innovation and precision in advancing patient care.
Related PRODUCTS
Understanding Monkeypox Testing PCR – Global Health & Diagnostic Insights
NewsNov.24,2025Comprehensive Guide to Monkey Pox Detection: Methods, Applications & Innovations
NewsNov.23,2025Essential Guide to Monkeypox Detection: Technologies, Applications & Future Trends
NewsNov.23,2025Understanding Strep B Test Cost: Global Insights and Healthcare Impact
NewsNov.22,2025Group B Strep DNA Test – Fast, Accurate Screening to Prevent Neonatal Infection
NewsNov.21,2025Essential Guide to Group B Strep Test Kits: Benefits, Uses & Innovations
NewsNov.20,2025