Cowingene HPV 28 Genotyping Detection Kit (Liquid)

Probă validată: tampon de col uterin, urină, analiți vaginali auto-colectați: 1 tub; ,55,56,58,59,61,66,68,73,81,82,83



Cowingene HPV 28 Genotyping Detection Kit(Liquid)


 
Intented Use

The HPV 28 Genotyping Detection Test is an in vitro diagnostic test for the qualitative detection of DNA from Human Papillomavirus (HPV) in patient specimens. The test utilizes amplification of target DNA by the Polymerase Chain Reaction (PCR) for the detection of 28 HPV types in 8 analysis. The test identifies types (6, 11, 16, 18, 26, 31, 33, 35, 39, 40, 42, 43, 44, 45, 51, 52, 53, 54, 56, 58, 59, 61, 66, 68, 73, 81, 82 and 83).

 

Order Information

REF Product Name Type Package Size
HP04021V Cowingene HPV 28 Genotyping Detection Kit Lichid 20 tests/kit

 

Specification

Detection Target
6, 11, 16, 18, 26, 31, 33, 35, 39, 40, 42, 43, 44, 45, 51, 52, 53, 54, 56, 58, 59, 61, 66, 68, 73, 81, 82 and 83
Certification
CE- IVD
Storage
≤-20℃ for 18 months
LoD
100 Copies/mL
Validated Specimen
urine, cervical swab
Compatible Instruments
Open real time PCR machine with channels FAM, VIC/HEX, ROX, CY5, i.e. ABI 7500, Roche 480, Bio-Rad CFX96, etc.

 

Performance Characteristics

Cross-reactivity

All results are negative when the kit is used to detect non-specific specimens that may have cross reactions with it, including ureaplasma urealyticum, chlamydia trachomatis of reproductive tract, candida albicans, neisseria gonorrhoeae, trichomonas vaginalis, mold, gardnerella and other HPV types not covered by the kit.

Interfering  Substances

The following substances: hemoglobin (200mg/L), white blood cells (10^9), Metronidazole (2mg/mL), cervical mucus, jieeryin lotion, fuyanjie lotion, human lubricant do not affect the test results of the kit.

Competitive Interference

The HPV types tested in the same HPV Mix do not affect the test results of others.

Analytical Sensitivity

The detection limit of the 28 HPV types within the detection range of the kit (i.e., HPV 6, 11, 16, 18, 26, 31, 33, 35, 39, 40, 42, 43, 44, 45, 51, 52, 53, 54, 56, 58, 59, 61, 66, 68, 73, 81, 82 and 83) is 100 Copies/mL.

Precision

The %CV of inter/intra day, inter/intra batch and different operators/ sites are all ≤5.0% of each HPV type.

 

Recommended Supporting  Reagents

REF Product Name Certification Package Size
CW03021Q Cowingene Sample Collection Kit(Self-collected vaginal) CE 1test/kit
CW04021Q Cowingene Sample Collection Kit(Self-collected urine) CE 1test/kit
CW01021Y Coloana ADN/ARN viral Cowingene CE 50tests/kit
CW02021Z Reactiv de eliberare a probei Cowingene CE 100mL(10*10mL)
CW05021X Cowingene DNA/RNA Extraction kit CE 48 teste/kit

Descărcați

Download(encryption)

If you are interested in our products, you can choose to leave your information here, and we will be in touch with you shortly.


Scrie mesajul tău aici și trimite-l nouă

Înrudit Ştiri

Dacă sunteți interesat de produsele noastre, puteți alege să lăsați informațiile dvs. aici și vă vom contacta în scurt timp.