Cowingene Monkeypox Virus Detection Kit (Lyophilized)
The Cowingene Monkeypox Virus Detection Kit (MPXV Detection Kit) is intended for the in vitro qualitative detection of Monkeypox Virus (MPXV) in Lesion material (swabs of surface or exudate, or crusts), Anorectal swab, Oropharyngeal swab, and provides aid to the diagnosis and treatment of patients with Mpox virus infections.
Monkeypox virus (MPXV) is a zoonotic virus in the family Poxviridae, genus Orthopoxvirus. The virus causes a disease in humans that is similar to smallpox, but results in a lower case-fatality rate. With the eradication of smallpox and widespread discontinuation of smallpox vaccination, human monkeypox has re-emerged as a human health threat with major outbreaks occurring in 1996-1997 and 2022. More recently, MPXV was found to be the cause of a cluster of cases of disease in many countries.
The MPXV Detection Kit adopts the method of PCR amplification combined with fluorescent probes, to select the conserved regions specific to Monkeypox Virus as the detection target genes, and an endogenous internal control is introduced as a quality control of the kit.
Order Information
РЕФ | Product Name | Type | Package Size |
ST07012X | Cowingene Monkeypox Virus Detection Kit | Лиофилизированный | 48 tests/kit |
Specification
Detection Target |
Monkeypox Virus |
Certification |
CE-IVD |
Storage |
2-30℃ for 18 months |
LoD |
The LoD of the kit for detecting Monkeypox Virus is 100 copies/mL. |
Validated Specimen |
Lesion material (swabs of surface or exudate, or crusts), Anorectal swab, Oropharyngeal swab, |
Compatible Instruments |
Open real time PCR machine with channels FAM, VIC/HEX, ROX, CY5, i.e. ABI 7500, Roche 480, Bio-Rad CFX96, etc. |
Storage And Handling Requirements
A. Reagents can be stored at 2-30℃ for 18 months.
B. Reagents can be transported at 2-30℃ for no more than 15 days.
C. Do not use reagents past expiration date indicated on outside of package.
D. Protect from light.
E. Once opened, Buffer Lypbeads is valid for 7 days at 2-8℃.
F. Once added PCR Solution, positive control, negative control and Primer Lyobeads are valid for 7 days at 2-8℃, 1 month below -20℃. Repeated freezing and thawing should be limited to 10 cycles.
Recommended Supporting Reagents
РЕФ | Product Name | Certification | Package Size |
CW03021Q | Cowingene Sample Collection Kit(Self-collected vaginal) | CE | 1test/kit |
CW04021Q | Cowingene Sample Collection Kit(Self-collected urine) | CE | 1test/kit |
CW01021Y | Колонка вирусной ДНК/РНК Cowingene | CE | 50tests/kit |
CW02021Z | Реагент для выпуска образца Cowingene | CE | 100mL(10*10mL) |
CW05021X | Cowingene DNA/RNA Extraction kit | CE | 48тестов/набор |