Cowingene Diarrhea Virus Panel 6 Detection Kit (Lyophilized)
Intented Use
The Cowingene Diarrhea Virus Panel 6 Detection Kit (GI 6 Detection Kit) is an in vitro diagnostic test for the qualitative detection of RNA from Norovirus GI (NoV-GI), Norovirus GII (NoV-GII), Adenovirus (AdV), Sapovirus (SV), Astrovirus (AstV), Rotavirus Group 4 (RVG4) in patient specimens. The test utilizes amplification of target RNA by the Polymerase Chain Reaction (PCR) for the detection of NoV-GI, NoV-GII, RVG4, SV, AdV, AstV in two analysis. The test specifically identifies NoV-GI, NoV-GII, RVG4, SV, AdV and AstV.The validated specimen including feces, vomit.
The collected specimen should be tested as soon as possible. If the specimens can not be tested immediately, please store them at 2-8℃ for no more than 7 days, below-18℃ for no more than 6 months, below-70℃ for a long time. The number of repeated freezing and thawing should be no more than 5 cycles.
Order Information
ÁRBITRO |
Product Name |
Type |
Package Size |
GI05022U |
Kit de detección del virus de la diarrea de Cowingene, panel 6 |
Liofilizado |
16 tests/kit |
Specification
Detection Target
Norovirus GI (NoV-GI), Norovirus GII (NoV-GII), Adenovirus (AdV), Sapovirus (SV), Astrovirus (AstV), Rotavirus (RotV)
Storage
2-30℃ for 18 months
LoD
NoV-GI: 400 copies/mL.
NoV-GII: 400 copies/mL.
RVG4: 400 copies/mL.
SV: 400 copies/mL.
AdV: 400 copies/mL.
AstV: 400 copies/mL.
Validated Specimen
Feces, Vomit
Compatible Instruments
Open real time PCR machine with channels FAM, VIC/HEX, ROX, CY5, i.e. ABI 7500, Roche 480, Bio-Rad CFX96, etc.
Performance Characteristics
1. Use the kit to detect the company positive reference panels and company negative reference panels, and the results should all meet the test requirements.
2. Repeatability: Use the kit to detect the repeatability reference panels and CV≤5% should be calculated based on the Ct (n=10).
Storage and Handling Requirements
A. Reagents can be stored at 2-30℃ for 18 months.
B. Reagents can be transported at 2-30℃ for no more than 15 days.
C. Do not use reagents past expiration date indicated on outside of package.
D. Protect from light.
E. Once opened, Buffer Lypbeads is valid for 7 days at 2-8℃.
F. Once added PCR Solution, positive control, negative control and Primer Lyobeads are valid for 7 days at 2-8℃, 1 month below -20℃. Repeated freezing and thawing should be limited to 10 cycles.
Recommended Supporting Reagents
ÁRBITRO |
Product Name |
Certification |
Package Size |
CW10021Y |
Columna de ADN/ARN viral de Cowingene |
CE |
50 tests/kit |
CW05021X |
Cowingene DNA/RNA Extraction kit |
CE |
48 tests/kit |